12) Feed power cable assembly through the rectan-

gular window on the bottom of the generator.

13) Connect power cable/thermostat assembly and

the existing cables to the negative brushholder
using the .75” long 5/16” hex head cap screw,
(provided in the mounting hardware packet).
Make certain the thermostat assembly does not
touch the brushholder spring and the cable is
clear of any moving parts. Make certain the ther-
mostat is assembled under the cable connec-
tions. (1/2” socket, ratchet, small extension).

14) Reposition the brush wraparound cover and

tighten with the hardware removed in step 8.
Keep the tightening flanges below the 3:00
position. (Large flat head screwdriver and pliers.)