Linear DVS-2400 User Manual

Page 11

Advertising
background image

9

EXTERNAL CONSOLE SPEAKER CONNECTION

✦ An external console speaker sounds system tones

and alerts occupants with a loud siren during alarm.

✦ With the VB-2 module installed, the Central Station

can talk to the occupants through the external
console speaker.

✦ Use an 8-ohm, 10 watt minimum rated speaker. Do

not use a horn/siren with a built-in siren driver.

✦ Up to two 8-ohm speakers can be used with each

Console.

✦ Up to 150 feet of 22 AWG wire can be used with

each speaker.

✦ The system tone volume can be adjusted with the

annunciator volume control.

1. Mount the external speaker.

2. Route the speaker wires from the external speaker

to the Console.

3. Open the Console top cover and locate the main

terminal block.

4. Route the speaker wires up through the wiring

access hole.

5. Remove the wire jumper from the EXT. SPKR & (-)

terminals.

6. Connect the speaker wires to the EXT. SPKR & (-)

terminals.

NOTE: If connecting two external speakers,

connect the second speaker in parallel, to the
same EXT. SPKR & (-) terminals as the fi rst
speaker.

EXTERNAL ALARM SIREN CONNECTION

✦ An external siren alerts occupants and neighbors

with a loud siren during alarm.

✦ Use a 12 volt, 1 amp maximum rated weather-

resistant horn speaker with a built-in siren driver. Do
not use a plain speaker.

NOTE: Connection of an electromechanical bell or

motor bell is not recommended because of the radio
interference generated when the bell is running.

UL NOTE: Not for use in UL installations.
1. Mount the external siren.

2. Route the wires from the external siren to the

Console.

3. Open the Console top cover and locate the main

terminal strip.

4. Route the siren wires up through the wiring access

hole.

5. Connect the siren wires to the RELAY N.O. & (-)

terminals.

NOTE: By removing the Console’s auxiliary fuse,

the relay contacts will become isolated. Use the
RELAY N.O. & RELAY DRY terminals to switch an
externally powered load.

AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY

MAIN TERMINAL BLOCK

EXT. SPKR(S)

8 OHM/10 WATT

2 SPKRS MAX.

NOTE: REMOVE

JUMPER FOR

EXT. SPEAKERS

OPTIONAL

VOICE MODULE

MODEL: VB-2

MAIN

TERMINAL

BLOCK

ANNUNCIATOR

VOLUME

CONTROL

LINEAR SECURITY CONSOLE MODEL DVS-2400

CONNECT SPEAKER LEADS
TO EXT. SPKR & (-) TERMINALS

REMOVE
JUMPER

EXTERNAL

CONSOLE

SPEAKER

8 OHM, 10 WATT

MINIMUM

AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY

MAIN TERMINAL BLOCK

EXTERNAL SIREN

12 VDC 1 AMP

MAXIMUM

OPTIONAL

VOICE MODULE

MODEL: VB-2

MAIN

TERMINAL

BLOCK

LINEAR SECURITY CONSOLE MODEL DVS-2400

EXTERNAL

CONSOLE

SPEAKER

EXTERNAL

ALARM

SIREN

CONNECT SIREN LEADS TO
(-) & RELAY N.O. TERMINALS

EXTERNAL

ALARM RELAY

12 VDC 1 AMP

MAXIMUM

Advertising