Linear DVS-2400 User Manual

Page 9

Advertising
background image

7

10 AUXILIARY

FUSE

★ Type 2AG, 1-amp fuse.

★ Protects the external relay output when used with wet contacts (12 VDC

switched out).

★ Fuse will blow when load exceeds 1 amp.

WARNING: For continued protection against the risk of fi re, replace only

with the same type and rating of fuse.

11

MAIN TERMINAL BLOCK

★ Terminals for connection to the plug-in AC transformer.

★ Terminals for connection to an external siren speaker.

★ Automation Output to connect to an automation controller.

★ External relay output for “wet” contacts (switched 12 volts) or “dry” contacts

(normally open 1 amp @ 24 volts maximum).

12 BATTERY

FUSE

★ Type 2AG, 3-amp fuse for the backup battery.

★ If the POWER light is fl ashing and the optional backup battery is installed and

charged, check this fuse.

WARNING: For continued protection against the risk of fi re, replace only

with the same type and rating of fuse.

13 TELEPHONE TERMINAL BLOCK

★ Provides telephone connections for the digital communicator.

★ Provides telephone connection for voice prompted telephone remote control

(optional VB-2 digital voice response module required).

★ Provides seized ring and tip connections for local telephone instruments.

Communicator will disconnect local telephones while on-line.

14 INTERNAL SPEAKER CONNECTOR

★ Connects the internal speaker to the Console circuit board.

★ 2-pin connector, non-polarized.

15 ANTENNA

TERMINALS

★ Antenna and ground terminals for receiving signals from the system's sensors.

★ Pre-wired to the Console's internal wire dipole antenna.

★ Alternately connects to the Model LA-P local whip and remote antenna kit.

16 OPTIONAL BACKUP BATTERY

★ Space for 12-volt, 1.2 amp/hour backup battery. (Highly recommended.)

★ Backup battery is automatically charged and monitored by the Console.

★ Backup battery can power the Console for up to 6 hours.

UL NOTE: Normal estimated battery life should be 3 to 4 years.

17 WIRING ACCESS HOLE

★ Provides access to recessed wiring trough in base of Console.

★ Route cables for power, telephone, external speaker, etc. through this hole.

★ Loop for zip-tie strain relief provided next to hole.

18 WALL-MOUNT

SLOTS

★ Used when mounting Console recessed in the wall.

★ Two mounting brackets (supplied) slide through slots and are retained by

screws, clamping the unit to the wall.

19 RADIO TEST POINTS

★ Used to monitor the Console's radio receiver during troubleshooting.

★ Provides connection for an audio amplifi er to listen to the receiver's output.

★ Helpful to determine sources of radio interference.

20 MICROPHONE (WITH MODEL VB-2 INSTALLED ONLY)

★ High sensitivity microphone.

★ Detects room audio when communicator is reporting to the Central Station

in 2-way audio mode (Model VB-2 digital voice synthesis module must be
installed).

21 ANNUNCIATOR VOLUME CONTROL

★ Varies the volume of the advisory tones that come from the speaker.

★ Does not affect internal or external sirens (they are always full volume).

22 DIGITAL VOICE SYNTHESIS MODULE (OPTIONAL)

★ The Model VB-2 gives the Consoles's digital communicator listen-only, manual

2-way and full duplex 2-way audio capability with the Central Station.

★ The module allows remote command of the system using a standard pushbutton

telephone, on or off site.

★ The module provides optional voice prompts from the Console’s speaker.

★ Units programmed for two-way duplex can still be controlled manually by

pressing the “1” or “3” key.

★ The Central Station can now return the unit to two-way duplex by pressing the

“8” key.

10

11

12

22

13

14

21

20

15

16

17

18

19