Typical system sensors – Linear DVS-2400 User Manual

Page 7

Advertising
background image

5

DOOR/WINDOW SENSOR

✦ Sensor mounts on door or window with adjacent

magnet.

✦ Opening door or window moves magnet away,

triggering sensor.

✦ Pressing the case causes sensor to send a test

signal.

✦ Jumper inside for INSTANT or DELAYED alarm

setting.

✦ Press the case for testing, the red transmit light

shows that battery is in good condition.

✦ Internal lithium batteries are monitored by the

Console.

✦ Sends hourly status reports to the Console.
✦ Up to 3 years battery life (depends on frequency of

activation). (UL tested for 1 year minimum.)

✦ Sensor contains internal terminals for connection to

glass break detector and external switches.

WIRELESS KEYPAD

✦ For controlling the system remotely without having

to go to the Console.

✦ Green operation light.
✦ Internal 9-volt battery is monitored by the Console.
✦ Keypad's beeper will buzz during transmissions

when the battery is low.

✦ Up to 3 years battery life (depends on frequency of

activation). (UL tested for 1 year minimum.)

✦ Sends hourly status reports to the Console.
✦ Press

to activate the automation output.

✦ Pressing clears the keypad.
✦ Pressing for two seconds sounds the mode

Beeps from the Console.

✔ Off Mode: 1 “Gong”.
✔ Chime Mode: 1 “Gong” & 1 “Beep”.
✔ Home Mode: 1 “Gong” & 2 “Beeps”.
✔ Away Mode: 1 “Gong” & 3 “Beeps”.
✔ Test Mode: 1 “Gong” & 4 “Beeps”.

✦ Emergency and fi re alarm can be triggered from the

wireless keypad at any time.

UL NOTE: For personal emergency use only. Not

for use as a UL Listed Medical Alert System.

ABOUT SENSOR STATUS SUPERVISION
All DXS Format sensors transmit hourly status reports. All DXT
Format sensors do not transmit hourly status reports. Both sensor
formats can be used with the Console.

When a sensor is programmed into the Console, the system will
set the sensor as non-supervised or supervised. Sensors set as
non-supervised are not expected to send hourly status reports.
Sensors set as supervised are expected to send hourly status
reports. If a status report is not received in 8 hours from a sensor
set as supervised, the TROUBLE indicator will fl ash.

When sensors are programmed into the Console, ALL STATIONARY
SENSORS ARE SET AS SUPERVISED, ALL PORTABLE
SENSORS ARE SET AS NON-SUPERVISED.

If stationary DXT Format sensors have been programmed into the
Console, be sure to change their setting to non-supervised to prevent
TROUBLE indications. This will not prevent low battery monitoring.

If portable DXS Format sensors have been programmed into the
Console, and the installation requires supervision for specifi c
portable sensor(s), change the selected portable sensors setting
to supervised.

After programming the sensors, if changes are required, refer to
“Changing a Sensors Supervision” on Page 26 for details on
changing the way a sensor’s supervision is set.

3.

TYPICAL SYSTEM SENSORS

WIRELESS

KEYPAD

Advertising