Welding operation, Ibed in the, Operation – Lincoln Electric CLASSIC I SVM134-A User Manual

Page 23

Advertising
background image

WELDING OPERATION

TO USE THE CLASSIC I FOR DC
CONSTANT CURRENT STICK OR TIG
WELDING:

1.

Remove the flange nuts from the weld output ter-
minals and place the work and electrode welding
cables over the terminals. For positive electrode,
connect the electrode cable to the + terminal and
the work cable to –.

For negative electrode,

reverse the electrode and work cables at the
welder’s output terminals.

See Figure B.4.

Replace and tighten the flange nuts securely. Be
sure the connections are tight.

2.

Select the appropriate electrode.

3.

Attach the work clamp securely to the work you are
welding.

4.

Insert the electrode into the electrode holder.

5.

Start the engine. See

Engine Operation in this

section of the manual.

6.

Set the Idler Switch to "AUTO."

7.

Set the CURRENT RANGE SELECTOR to a set-
ting equal to or slightly higher than the desired
welding current.

8.

Set the FINE CURRENT ADJUSTMENT to the
setting that gives the best arc characteristics for
the range selected.

See

Control of Welding

Current in this section of the manual.

9.

Strike an arc and begin welding.

After you finish welding:

1.

Stop the engine. See

Engine Operation in this

section of the manual.

2.

Allow the electrode and work to cool completely.

3.

Remove the work clamp from the work.

4.

Remove any remaining piece of electrode from the
electrode holder.

OPERATION

B-9

B-9

CLASSIC I

FIGURE B.4 – WELDING CIRCUIT CONNECTIONS FOR STICK WELDING

1

7

6

5

4

2

3

1. OUTPUT TERMINALS
2. ELECTRODE CABLE
3. ELECTRODE HOLDER
4. ELECTRODE
5. WORK PIECE
6. WORK CLAMP
7. WORK CABLE

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Advertising