TROUBLESHOOTING & REPAIR

F-19

F-19

CLASSIC I

WARNING

MAIN GENERATOR SHUNT FIELD WINDING TEST

Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot-
ing assistance before you proceed. Call 1-800-833-9353 (WELD).

TEST DESCRIPTION

This test will help determine whether or not the main shunt field coils are shorted, open, or
grounded.

MATERIALS NEEDED

Volt/ohmmeter (Multimeter)
Wiring Diagram

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

This procedure takes approximately 25 minutes to perform.