TROUBLESHOOTING & REPAIR

F-34

F-34

CLASSIC I

DC EXCITER ARMATURE AND FIELD COILS

REMOVAL AND REPLACEMENT

(continued)

Field Coils Removal Procedure

1. Perform the

DC Exciter Armature Removal

Procedure.

2. Using the 3/8” wrench, remove the leads from

the brush holder.

Note lead placement for

reassembly.

3. Using the 1/2” wrench, remove the four bolts

(two on each side) holding the pole pieces to
the exciter frame.

See Figure F.12.

4. Label and remove the tape and splices from

the black and red leads that go to the idler
board and 115VDC receptacle.

See the

Wiring Diagram.

5. Carefully slide the coils and pole pieces from

the exciter frame.

6. Remove the coils from the pole pieces.

Reassembly:

7. Assemble the new coils to their respective

pole pieces.

8. Assemble the coil and pole pieces to the

exciter frame with four bolts.

9. Make the necessary lead connections to the

idler board and 115VDC receptacle. Wrap
the slices with tape.

10. Assemble the armature and brushes.

See the

DC Exciter Armature Removal

Procedure.