TROUBLESHOOTING & REPAIR

F-30

F-30

CLASSIC I

This is the typical DC welding output
voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division
represents 5 milliseconds in time.

Note: Scope probes connected at
machine output terminals.

SCOPE SETTINGS

Volts/Div .....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger .........................Internal

NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AND SELECTOR

SWITCH AT MAXIMUM

0 volts

5 ms

50 volts