Troubleshooting & repair – Lincoln Electric CLASSIC I SVM134-A User Manual

Page 73

Advertising
background image

TROUBLESHOOTING & REPAIR

F-29

F-29

CLASSIC I

This is the typical auxiliary output
voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division
represents 2 milliseconds in time.

Note: Scope probes connected at
machine 115VDC receptacle.

SCOPE SETTINGS

Volts/Div .....................50V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger .........................Internal

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VDC SUPPLY)

HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AT MAXIMUM

0 volts

2 ms

50 volts

Retur

n to Section TOC