Troubleshooting & repair, Caution – Lincoln Electric POWER MIG SVM165-A User Manual

Page 58

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

F-12

F-12

POWER MIG 350MP

TROUBLESHOOTING & REPAIR

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely,
contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

PUSH PULL WIRE FEEDING PROBLEMS

While loading wire the wire bird
nests if the wire misses the outlet
guide while shooting the gap in the
torch.

1. Straighten the first six inches of

the wire before feeding it into the
rear wire drive.

2. Make sure the torch drive rolls

are tightened slightly to help the
wire jump the gap.

3. Slow down wire feed speed while

pushing wire through torch liner.
Recommended setting = 350
ipm.

4. If problem continues after a thru c

are checked then the Stall Factor
Number needs to be decreased.
See Stall Factor Number
Adjustment.

CAUTION

Arc length varies while welding (arc
length is not constant).

1. Power Mig 350MP drive rolls set

to tight. The tension arm should
be set at 1 to 1-1/2.

2. Check to see that the spindle

brake is not set too tight. There
should be an aluminum spacer
behind the spindle brake. Refer
to the push-pull connection kit for
this spacer.

3. Clean or replace contact tip.

4. If problem continues after a thru c

are checked then the Stall Factor
Number needs to be increased.
See Stall Factor Number
Adjustment.

Observe Safety Guidelines
detailed in the beginning of this manual.