Troubleshooting & repair, Encoder pc board test (continued) – Lincoln Electric POWER MIG SVM165-A User Manual

Page 78

Advertising
background image

TROUBLESHOOTING & REPAIR

F-32

F-32

POWER MIG 350MP

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

ENCODER PC BOARD TEST

(continued)

FROM LEAD TO LEAD EXPECTED VOLTAGE

855

3243

15 VDC

5J85

3J82

8511

3243

0 OR 15 VDC

11J85

3J82

858

3243

0 OR 15 VDC

8J85

3J82

VOLT/TRIM ENCODER #1

ACTION

If you do not read 15 VDC on the first reading of
encoder #1 or #2 then check lead connections. If lead
connections check OK, then Feeder Board may be
faulty, replace Feeder Board.

As you turn the encoder #1 or #2 slowly you should see
your meter go from 0 to 15, 0 to 15 as you turn the
encoder. If not, check the lead connections. If the lead
connection check OK then, change the encoder.

FROM LEAD TO LEAD EXPECTED VOLTAGE

859

3243

15 VDC

9J85

3J82

857

3243

0 OR 15 VDC

7J85

3J82

WMF/AMPS ENCODER #2

ACTION

If you do not read 15 VDC on the first reading of
encoder #1 or #2 then check lead connections. If lead
connections check OK, then Feeder Board may be
faulty, replace Feeder Board.

As you turn the encoder #1 or #2 slowly you should see
your meter go from 0 to 15, 0 to 15 as you turn the
encoder. If not, check the lead connections. If the lead
connection check OK then, change the encoder.