CURRENT TRANSDUCER TEST (continued)

FIGURE F.10

L11088-1

J8

804

802

801

806

TEST PROCEDURE

1. Remove input power to the machine

2. Remove the left case side of the machine.

3. Remove the PC Board compartment door.

4. Locate plug J8 at the Control Board. See Figure

F.10.

5. Connect the main power to the machine.

6. Make the following voltage test. From the table

below. Also see Table F.2.

7. Carefully insert the meter probes into the back of

each Molex plug pin cavity.

8. If expected voltages are not present the Control

Board may be faulty.

9. Check the feedback voltage from the current

transducer with the Power MIG set on Mode 100
and the machine loaded to 250 amps.

10. Make the following voltage test. From the table

below.

11. If the measured feedback voltage is not correct for

the output load current. The current transducer
may be faulty.

12. If for any reason the machine cannot be loaded to

250 amps, Table F.2 shows what feedback volt-
age is produced at various current loads.

FROM LEAD TO LEAD EXPECTED VOLTAGE

802+

806- +15 VDC

(2J8) (6J8)

FROM LEAD TO LEAD EXPECTED VOLTAGE

801

806 2.0 VDC

(1J8) (6J8)