TROUBLESHOOTING & REPAIR

F-21

F-21

POWER MIG 350MP

CHOPPER BOARD TEST

(continued)

FIGURE F.3 – CHOPPER BOARD CONNECTIONS

Table F.1– CHOPPER BOARD RESISTANCE TEST TABLE

TEST PROCEDURE

1. Disconnect the main AC input power to the

machine.

2. Remove the case side panels with a 3/8” nut driver.

3. Locate plug J99. (Later machine do not have J99).

4. Make the following voltage test. From the table

below.

5. Turn the machine off between each test:

a. Carefully insert the meter probes into the back of

each Molex plug cavity.

If 20 VDC is not present check Digital Power Supply.

See the Wiring Diagram.

RESISTANCE TEST

1. Perform the Capacitor Discharge Procedure.

2. Remove input power to the machine.

3. Perform the resistance tests in Table F.1.

300 CHOPPER

C12

+

C1

+

C4

C2

C3

+

+

+

+

_

_

_

_

C11

C10

C8

C9

B1

B4

B5

B6

B3

B2

B5

B2

B1

B3

B6

B4

J99

FROM

LEAD

TO

LEAD

EXPECTED

VOLTAGE

437+(1J99)

431-(4J99)

20VDC

Test Point

B5(+)
B6(+)
B4(+)
B5(+)
B4(+)
B6(+)
B2(+)
B3(+)
B4(+)
B2(+)
B4(+)
B3(+)

Test Point

B6(-)
B5(-)
B5(-)
B4(-)
B6(-)
B4(-)
B3(-)
B2(-)
B2(-)
B4(-)
B3(-)
B4(-)

Expected Reading

6 K ohms - 9K ohms
6 K ohms - 9K ohms

200 K ohms or Higher
400 K ohms or Higher
200 K ohms or Higher
400 K ohms or Higher

6 K ohms - 9K ohms
6 K ohms - 9K ohms

200 K ohms or Higher
400 K ohms or Higher
200 K ohms or Higher
400 K ohms or Higher

Advertising