TROUBLESHOOTING & REPAIR

F-26

F-26

POWER MIG 350MP

OUTPUT RECTIFIER ASSEMBLY TEST

(continued)

FIGURE F.7– OUTPUT RECTIFIER ASSEMBLY LOCATION

TEST PROCEDURE

1. Disconnect the main AC input power to the

machine.

2. Perform the Chopper Assembly Capacitor

Discharge procedure.

3. Locate and disconnect the negative lead from the

output rectifier bridge assembly.

Note: Do not disassemble the rectifier assembly.

4. Test for shorted or leaky diodes by checking from

the outside plate (A) to inside plate (A) then reverse
your leads and recheck the same plates. Do the
same to plate B. The readings should be high resis-
tance in one polarity and low resistance in the oppo-
site polarity. See Figure F.7.

5. If any of the diodes are leaky or shorted the output

rectifier assembly should be replaced.

6. When the test is complete, replace the negative out-

put previously removed.

7. Replace case side.