Installation, Restrictor position # 5, Restrictor position # 6 – Lopi Direct Vent Freestanding Stove User Manual

Page 13

Advertising
background image

Installation

(for qualified installers only)

1 3

Travis Industries

1 0 0 - 0 1 1 8 7 _ 0 0 0

4 0 7 0 2 1 9

Vertical Termination with Zero, Two, or Four 45° Elbows

The termination must fall
within the shaded area
shown in the chart. Use
the indicated restrictor
position.

If using offsets, use the
table below to calculate the
vertical rise and horizontal
offset

Offset
Length

Horizontal
Offset

Vertical

Rise

Offset Length

Hor. Offset

Vert. Rise

None

5”

1’

1’ Section

1’

1’ 7”

2’ Section

1’ 9”

2’ 4”

3’ Section

2’ 5”

3’

4’ Section

3’ 2”

3’ 8”

4’ + 1’ Section 3’ 9”

4’ 4”

4’ + 2’ Section 4’ 6”

5’

4’ + 3’ Section 5’ 2”

5’ 9”

4’ + 4’ Section 6’

6’ 9”

5 feet

10 feet

15 feet

20 feet

25 feet

30 feet

0 feet

40' (max)

5 feet

0 feet

0 feet

5 feet

10 feet

15 feet

20 feet

25 feet

30 feet

40' (max)

Restrictor

Position # 5

NOTE:

Restrictor positions are based

upon lab tests. The ideal

restrictor position may vary

slightly, especially when the

termination is near a

demarkation line.

Restrictor

Position # 6

10 feet

15 feet

20 feet

24 ' (max)

0 feet

5 feet

10 feet

15 feet

20 feet

24 ' (max)

35 feet

35 feet