Installation, Horizontal termination with one 90° elbow – Lopi Direct Vent Freestanding Stove User Manual

Page 14

Advertising
background image

1 4

Installation

(for qualified installers only)

Travis Industries

1 0 0 - 0 1 1 8 7 _ 0 0 0

4 0 7 0 2 1 9

Horizontal Termination with One 90° Elbow

If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

10 feet

15 feet

19' (max)

0 feet

5 feet

0 feet

0 feet

5 feet

10 feet

15 feet

Restrictor Position # 5

NOTE:

Restrictor positions are based

upon lab tests. The ideal

restrictor position may vary

slightly, especially when the

termination is near a

demarkation line.

Restrictor

Position # 1

10 feet

15 feet

20 feet

24 ' (max)

0 feet

5 feet

10 feet

15 feet

20 feet

24 ' (max)

19' (max)

NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.

NATURAL GAS: Min. 2' Section Required

PROPANE (LP): Min. 3' Section Required