Optional equipment – Lopi Direct Vent Freestanding Stove User Manual

Page 40

Advertising
background image

40

Optional Equipment

(for qualified installers only)

Travis Industries

1 0 0 - 0 1 1 8 7 _ 0 0 0

4 0 7 0 2 1 9

5

Install the logs and
embers.

6

Replace glass and
face.

7

Remove the
regulator from the
front of the gas
control valve.
Replace with the
propane regulator,
using the new
gasket and screws
included with the
regulator. NOTE:
Leak test this
area after the
heater is
installed, gas is
c o n n e c t e d ,
and the main
burner is lit.

Place the LP label on top of
the control cover near the gas
control valve.

d

Remove and discard the three screws using a
slotted screwdriver of Torx T-20.

NOTE: Make sure the
regulator gasket is correctly
aligned before installation.

Remove and discard the
regulator, diaphram, spring
and center post.

a

b

Slotted

Screwdriver

(or T-20 Torx)

Install the LP regulator. Use the screws
included with the LP regulator. Tighten to
approximately 25 Lbs. torque.

c

Slotted

Screwdriver

(or T-20 Torx)

8

Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all
gas connections and the gas control valve. Check the pilot. Adjust if necessary.

WARNING:

When lighting or re-lighting the pilot, the glass must be removed (see
page 24).

Standard
Screwdriver

The pilot flame must contact the thermocouple and

thermopile (see the illustration below). Adjust the pilot up or

down as necessary.

To adjust the pilot flame, turn this screw (NOTE: if totally

unscrewed gas will come out of this port). Clockwise

lowers the flame while counter-clockwise raises it.

Advertising