Optional equipment, Accent light, For qualified installers only) – Lopi Direct Vent Freestanding Stove User Manual

Page 43

Advertising
background image

Optional Equipment

(for qualified installers only)

4 3

Travis Industries

1 0 0 - 0 1 1 8 7 _ 0 0 0

4 0 7 0 2 1 9

Accent Light

(Type 2 – 94400111)

Make sure power to the heater has been turned off prior to installation (unplug the power cord).

Do not connect 110-120 VAC to the gas control valve or the on/off circuit on this fireplace.

IMPORTANT INSTALLATION NOTE FOR MODELS USING THE FIREBACKS:

Follow the steps below if installing the firebacks with an accent light.

Remove the burner (see the manual for details).

Install the rear fireback (see the instructions included with the firebacks).

Install the accent light.

Replace the burner.

Install the side firebacks (see the directions included with the firebacks).

N O T E

:

The bulb may be shipped separately. Do not touch the bulb – oil or other residue left on the bulb
may lead to premature bulb failure. Use a cloth or paper towel to handle the bulb.

1

Modify the accent light assembly as shown in the illustration below.

Loosen these nuts

and slide the light

receptacle out (take

care to not touch the

halogen bulb)

Re-attach the

receptacle to the

opposite side.

Remove the screw

that holds the accent

light bracket in place.

Re-attach it in the

second hole from the

top. This lowers the

accent light for proper

light placement.

Accent Light Bracket

Bend this tab upwards

to a 90° angle.

a

b

c

2

Remove the burner from the stove (see owner’s manual for details). Install the accent light assembly as shown
in the illustration below.

Remove this screw on the firebox floor.

Position the accent light assembly in the

same location, and re-attach the screw

to secure the accent light assembly.

Remove and discard the cover

plate (accessed from below).

a

b

NOTE: The accent light requires the right side access hole. If

this hole is being used for the thermodisk for optional blower,

switch the thermodisk to the mounting position on the left side.

NOTE: To prevent heat-damage to the wires,

make sure this wires are routed along the

floor of the firebox, away from the burner.

Route the wires from the

accent light through gasket

and hole. Attach the accent

light cover plate (with

grommet) to the firebox floor

with the screws removed in

step “b”. Pull the excess

wire through the grommet,

towards the front of the stove

(this helps prevent the wire

from contacting the burner).

c