Operation

Travis Industries

1 0 0 - 0 1 1 8 7 _ 0 0 0

4 0 7 0 2 1 9

Before You Begin

Warning: Read this entire manual before you use your new stove (especially the section "Safety

Precautions" on pages 4 & 5). Failure to follow the instructions may result in property
damage, bodily injury, or even death.

Warning

:

Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass
should be done by a licensed or qualified service person.

Location of Controls - See explanation below

Swing the control cover

down to access the gas control

valve and pilot igniter.

The Pilot Flame

can be found below

the back log.

IGNITER

Pilot Igniter

ON/OFF

Switch

The on/off switch and optional blower

control are located on the back of the

heater.

Gas

Control

Valve

Gas Control Knob

Flame Adjust Knob

An instruction card for operating the fireplace

is attached to the inside of the fireplace here.

Replace it for easy reference.

ON

OFF

Optional

Blower

Control

On/Off Switch

This control is used to turn the flame on and off.

Optional Blower Control

This knob controls the speed of the internal convection blower that
pushes heated air into the room.

Gas Control Knob

This knob controls gas to the stove and pilot. There are three positions: ON,
OFF, and PILOT. The indicator line is to the left of the knob.

Flame Adjust Knob This knob controls the flame height from low ("LO") to high ("HI”). The

indicator line is above the knob.

Pilot Igniter

The pilot igniter is used only to start the pilot. When pressed, it sends an
electrical charge to the pilot assembly. This creates a blue spark directly next
to the pilot, igniting the pilot flame.

If using a remote control or thermostat, the On/Off Switch must be left "OFF". Turning the On/Off
Switch "ON" will keep the stove on always.