Optional equipment, For qualified installers only) – Lopi Direct Vent Freestanding Stove User Manual

Page 39

Advertising
background image

Optional Equipment

(for qualified installers only)

3 9

Travis Industries

1 0 0 - 0 1 1 8 7 _ 0 0 0

4 0 7 0 2 1 9

3

Follow the directions below to replace the orifice.

1/2" Wrench

Use a 1/2” open end wrench to
unscrew the burner orifice.

NOTE:

Screw the LP orifice in
so the orifice shoulder

protrudes 5/16”
(indicating full insertion).

37

.062

The new LP orifice has

“.062” stamped on it.

The old NG
orifice has “37”

stamped on it.

Apply thread
sealant to the

new orifice and
install.

5/16”

Remove the four screws holding the

mixing tube in place.

Remove the mixing tube from the
air shutter by sliding it to the left.

1/4" Nutdriver

Air Shutter

a

b

Slide the air shutter to the fully

open position.

Manifold

Burner Orifice

c

d

e

4

Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice

Lift the pilot hood

off the pilot

assembly.

5/32" Hex

Use a hex wrench to

unscrew the orifice.

Remove the orifice and replace with the LP orifice. Screw the

orifice all the way in and replace the pilot hood.

LP (Propane) Orifice

Orifice Identification:

NG (Natural Gas) Orifice

35

62

35

a

b

c

NOTE: when re-attaching,

this pin lines up with the

notch in the pilot hood.

Advertising