Installation, Horizontal termination with two elbows – Lopi Direct Vent Freestanding Stove User Manual

Page 15

Advertising
background image

Installation

(for qualified installers only)

1 5

Travis Industries

1 0 0 - 0 1 1 8 7 _ 0 0 0

4 0 7 0 2 1 9

Horizontal Termination with Two Elbows
(

one 90° vertical and one 90° or 45° horizontal elbow

)

If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

10 feet

15 feet

19' (max)

0 feet

5 feet

0 feet

0 feet

5 feet

10 feet

15 feet

Restrictor

Position # 5

NOTE:
Restrictor positions are based upon lab
tests. The ideal restrictor position may vary
slightly, especially when the termination is
near a demarkation line.

Restrictor

Position # 1

10 feet

15 feet

20 feet

24 ' (max)

0 feet

5 feet

10 feet

15 feet

20 feet

24 ' (max)

19' (max)

NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.

This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.

This is considered a
vertical elbows

Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).

H1

H2

NATURAL GAS: Min. 2' Section Required

PROPANE (LP): Min. 3' Section Required