TROUBLESHOOTING & REPAIR

F-9

IDEALARC DC-1000

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Machine shuts off (input contac-
tor drops out) when the welder
output terminals are electrically
energized. (#2 to #4 closure at
terminal strip.)

The DC-1000 will NOT shut off
when the Stop button is pushed.

1. Remove all welding cables

and control cables from the
DC-1000. Jumper #2 to #4 at
the terminal strip. If the
machine does NOT shut off
and normal open circuit volt-
age is present at the welder
output terminals, the problem
is external to the DC-1000.
Either the remote leads #73,
#74, #75, #76 or #77 are
grounded to the negative out-
put cable, or there is a short
on the welding output termi-
nals.

2. If the machine still shuts off

when all control and welding
cables are removed, then the
problem is internal to the DC-
1000.

1. Contact your local Lincoln

Authorized Field Service
Facility.

1. Check for grounds and or

shorts in the #73, #74, #75,
#76, #77 circuit. See wiring
diagram.

2. Check for grounds and shorts

in the welder output terminals
and associated leads. See
wiring diagram.

3. Check the output shunt and

associated leads. See wiring
diagram.

4. Perform the

Control Board

Test.

1. The input contactor (1CR)

contacts may be stuck closed.
Check and replace if neces-
sary.

2. The Interlock contacts (part of

1CR) may be faulty. Replace
if necessary.

3. The Start/Stop button may be

faulty. Check or replace.