TROUBLESHOOTING & REPAIR

REMOVAL OF INDIVIDUAL
SCR HEAT SINK ASSEMBLIES

1.

Using a 9/16” wrench, remove two
nuts, flat washers, and lock wash-
ers from the SCR assembly mount-
ing studs. See Figure F.24.

2.

Using a 5/16 (8mm) nut driver or
flat head screw driver, remove
snubber ground wire attachment.
The snubber assembly can now be
removed. Replace if necessary.

3.

Carefully remove the positive buss
bar from the heat sink in question.
It may be necessary to remove the
buss bar completely.

4.

Carefully slide the SCR assembly
from the mounting studs.
Replacement will be made with a
new SCR assembly.

DO NOT DISASSEMBLE THE SCR
FROM THE HEAT SINK. MACHINE
DAMAGE MAY RESULT. REPLACE
THE SCR ONLY AS AN ASSEMBLY.

_______________________________________

SCR OUTPUT BRIDGE REPLACEMENT

IDEALARC DC-1000

FIGURE F.24 - Individual SCR Assembly Heat Sink Removal

CAUTION

F-52