Troubleshooting & repair, Caution – Lincoln Electric IDEALARC DC 1000 SVM123-A User Manual

Page 50

Advertising
background image

F-10

TROUBLESHOOTING & REPAIR

F-10

IDEALARC DC-1000

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

The weld output terminals are
always electrically “hot”.

1. Remove any external leads

hooked to #2 and #4 on the
terminal strip. If the problem
disappears, the fault is in the
control cable or wire feeder.

2. If some open circuit voltage is

present (over 3 VDC.) after
performing Step #1, then the
problem is within the DC-
1000.

1. Check for an internal short

between leads #2 and #4. See
wiring diagram.

2. The Pilot Relay (4CR) may be

stuck closed. Check or
replace.

3. Perform

Firing Board Test.

4. Perform

Control Board Test.

5. Perform the

SCR Output

Bridge Test.

6. The SCR Snubber(s) may be

“leaky”. Check or replace. See
wiring diagram.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

CAUTION