F-43

TROUBLESHOOTING & REPAIR

F-43

TYPICAL SCR GATE VOLTAGE WAVEFORM

CONSTANT VOLTAGE INNERSHIELD

MAXIMUM OUTPUT SETTING - NO LOAD

IDEALARC DC-1000

SCOPE SETTINGS

Volts/Div. . . . . . . . . . . . . . 1 V/Div.
Horizontal Sweep . . . . . .5 ms/Div.
Coupling . . . . . . . . . . . . . . . . . DC
Trigger . . . . . . . . . . . . . . . Internal

This is the typical SCR gate pulse volt-
age waveform. The machine was in an
open circuit condition (no load) and
operating properly. Note that each verti-
cal division represents 1 volt and that
each horizontal division represents 5
milliseconds in time.

Note: Scope probes connected at SCR
gate and cathode: (+) probe to gate, (-)
probe to cathode.