TROUBLESHOOTING & REPAIR

F-25

IDEALARC DC-1000

CONTROL BOARD TEST

Service and repair should be performed only by Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment could result in danger to the technician or
the machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.

If for any reason you do not understand the test procedures or are unable to perform the
tests/repairs safely, contact the Lincoln Electric service department for technical trou-
bleshooting assistance before you proceed.

Call (216) 383-2531 or (800) 833-9353 (WELD).

_____________________________________________________________

TEST DESCRIPTION

This test will determine if the Control Board is receiving the correct voltages and feedback
signals.

MATERIALS NEEDED

Volt/Ohm Meter (Multimeter)
IDEALARC DC-1000 Wiring Diagram and Control Board Schematic (See Electrical Diagram
Section of Manual).

WARNING