Innershield - maximum output setting - no load, Troubleshooting & repair – Lincoln Electric IDEALARC DC 1000 SVM123-A User Manual

Page 79

Advertising
background image

F-39

TROUBLESHOOTING & REPAIR

F-39

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

CONSTANT VOLTAGE INNERSHIELD - MAXIMUM

OUTPUT SETTING - NO LOAD

IDEALARC DC-1000

Volts/Div. . . . . . . . . . . . . 50 V/Div.
Horizontal Sweep . . . . . 2 ms/Div.
Coupling . . . . . . . . . . . . . . . . . DC
Trigger . . . . . . . . . . . . . . . Internal

SCOPE SETTINGS

This is the typical DC open circuit volt-
age waveform generated from a proper-
ly operating machine. Note that each
vertical division represents 50 volts and
that each horizontal division represents
2 milliseconds in time.

Note: Scope probes connected at
machine output terminals: (+) probe to
positive 1000 Amp terminal, (-) probe to
negative terminal.

Return to Section TOC