2) Sensor resistance characteristics table

u

Resistance value allowance of sensor is ±5%.

u

When measuring the resistance value of the sensor, allow the temperature of that sensor to stabilize for at least 3 minutes
before measuring. This delay is necessary because of the sense speed relationship.

u

Use a digital tester to measure the resistance. An analog tester has to great a margin of error.

u

Resistance of the cold storage sensor 1 and 2 shall be measured with a digital tester after separating CON8 of the PWB
ASSEMBLY and the MAIN part.

u

Resistance of the freezing sensor shall be measured with a digital tester after separating CON7 of the PWB ASSEMBLY
and the MAIN part.

EXPLATION FOR MICOM CIRCUIT

- 39 -

Measuring Temperature (°C)

Freezing Sensor

Refrigerator sensor 1&2

Defrost sensor, Ambient sensor

-20 °C

22.3 k

77 k

-15 °C

16.9 k

60 k

-15 °C

13.0 k

47.3 k

-5 °C

10.1 k

38.4 k

0 °C

7.8 k

30 k

+5 °C

6.2 k

24.1 k

+10 °C

4.9 k

19.5 k

+15 °C

3.9 k

15.9 k

+20 °C

3.1 k

13 k

+25 °C

2.5 k

11 k

+30 °C

2.0 k

8.9 k

+40 °C

1.4 k

6.2 k

+50 °C

0.8 k

4.3 k