Trouble d iagnosis – LG SXS GR-P257/L257 User Manual

Page 60

Advertising
background image

TROUBLE

D

IAGNOSIS

-5
8-

Problems

Causes

Checks

Measures

Remarks

High

Cycle pipe is clogged.

Check sequence.

- Heat up compressor discharging

Direr must be replaced.

temperature in

1. Check temperature of condenser

weld joints with touch, disconnect

the freezer

manually.

the pipes, and check the clogging.

compartment.

If it is warm, it is OK.

Remove the causes of clogging,

If it is not, compressor discharging

weld, evacuate, and recharge

joints might be clogged.

the refrigerant.

2. Manually check whether hot line

- If it's warm, it's OK. If it's not,

pipe is warm.

condenser discharging line weld

If it is warm, it's OK.

joints might be clogged.

If it is not, condenser outlet weld

Disconnect with torch, remove the

joints might be colgged.

causes, evacuate, and recharge

seal refrigerant.

Leak at loop pipe weld joint

Check sequence.

Replace the compressor, weld,

Drier must be replaced.

(discharge) in compressor.

1. Manually check whether

evacuate, and recharge refrigerant.

condenser is warm, It is not warm

and the frost forms partly on the

evaporator in the freezer

compartment.

Faulty cooling fan in the compressor Check sequence.

- Replace if motor does not operate.

compartment.

1. Check cooling fan operation.

- If fan is disconnected, check fan

2. Check that cooling fan is

damage and reassemble it.

disconnected from the motor.

■ Refer to fan motor disassembly

and assembly sequence.