Trouble d iagnosis – LG SXS GR-P257/L257 User Manual

Page 57

Advertising
background image

2. Faults

2-1. Power

2-2. Compressor

TROUBLE

D

IAGNOSIS

-5
5-

Problems

Causes

Checks

Measures

Remarks

No power on

- Power cord cut.

- Check the voltage with tester.

-Replace the components.

outlet.

- Faulty connector insertion.

- Check visually.

-Reconnect the connecting parts.

- Faulty connection between plug

- Check visually.

- Reconnect the connecting parts.

and adapter.

Fuse blows out. - Short circuit by wrong connection.

- Check the fuse with tester

- Find and remove the cause of

- Replace with rated

- Low voltage products are

or visually.

problem(ex. short, high voltage,

fuse after confirming

connected to high voltage.

- Check the input volt are with tester

low voltage).

its specification.

- Short circuit by insects.

(between power cord and products). - Replace with rated fuse.

- Electricity leakage.

- Check the resistance of power cord

■ If fuse blowns out

- High voltage.

with testerf (if it is 0

Ω, it is shorted).

frequently, reconfirm

- Short circuit of components

the cause and prevent.

(tracking due to moisture and dust

penetration).

Problems

Causes

Checks

Measures

Remarks

Compressor

- Faulty PTC.

- Check the resistance.

- If resistance is infinite, replace it

does not

Vlaue:

∞ is defective.

with new one.

operate.

- If it is not infinite, it is normal.

- Check other parts.

- Compressor is frozen.

- If compressor assembly parts are

- During forced operation:

normal(capacitor, PTC, OLP),

- Operates: Check other parts.

apply power directly to the

- Not operate: Replace the frozen

compressor to force operation.

compressor with new one, weld,

evacuate, and recharge refrigerant.

OLP It starts as soon as it is

• Refer to weld repair procedures.

contacted.

Auxiliary winding

Main winding

Power