2-3. Temperature

TROUBLE

D

IAGNOSIS

-5
6-

Problems

Causes

Checks

Measures

Remarks

High

Poor cool air circulation due to faulty

- Lock –– Check resistance with a

- Replace fan motor.

temperature

fan motor.

tester.

in the freezer

0

Ω: short.

compartment.

∞Ω: cut.

- Reconnect and reinsert.

- Rotate rotor manually and check

rotation.

- Wire is cut.

- Bad terminal contact: Check

- Maintain clearance and remove ice

terminal visually.

(Repair and/or replace shroud if fan

- Fan constraint. – Fan shroud

is constrained by shroud

contact: Confirm

deformation).

visually.

– Fan icing:

Confirm visually.

Faulty fan motor due to faulty door

- Iced button (faulty) operation:

- Confirm icing causes and repair.

switch operation.

Press button to check

- Replace door switch.

- Faulty button pressure and contact:

Press button to check operation.

- Door cannot press door switch

- Door sag: fix door.

button: Check visually.

- Door liner bent:replace door or

attach sheets.

Bad radiation conditions in

- Check the clearance between the

- Keep clearance between

- The fan may be

compressor compartment.

refrigerator and wall (50 mm in

refrigerator and walls (minimum

broken if cleaning

minimum).

50mm).

performs while the

- Check dust on the grill in

- Remove dust and contaminants

refrigerator is on.

compressor compartment.

from grill for easy heat radiation.

- Check dust on the coils condenser. - Remove the dust with vacuum

cleaner from the coils condenser

while the refrigerator is off.