Trouble d iagnosis – LG SXS GR-P257/L257 User Manual

Page 62

Advertising
background image

TROUBLE

D

IAGNOSIS

-6
0-

Problems

Causes

Checks

Measures

Remarks

No defrosting

Melting fuse blows out.

- Check melting fuse with tester. -

Faullty parts: parts replacement.

1) Lead wire is cut.

If 0

Ω: OK.

- Check wire color when maeasuring

2) Bad soldering.

If

∞Ω: wire is cut.

resistance with a tester.

Ice in the Sucking duct.

1. Check the inner duct with mirror.

1) Turn power off.

1) Icing by foreign materials in the

2) Raise the front side(door side),

duct.

support the front side legs, and let

2) Icing by cool air inflow through

the ice melt naturally. (If power is

the gap of heater plate.

on, melt the frost by forced

3) Icing by the gap of heater plate.

defrosting.)

2. Check by inserting soft copper

3) Reassemble the heater plate.

wire into the duct (soft and thin

copper not to impair heating wire).

Bad cool air inflow and discharge,

1. Turn on power, open or close the

1) Check the faulty connector of

and bad defrosting due to faulty

door, check that motor fan

housing and reassemble wrongly

contact and insertion (bad connector

operates (If it operates, motor fan

assembled parts.

insertion into housing of heater,

is OK).

2) If the parts are very damaged,

melting, fuse and motor fan).

2. Disconnect parts in the refrigerator

remove the parts and replace it

compartment, check the connection

with a new one.

around the housing visually,

defrost, and confirm heat generation

on the heater. Do not put hands on

the sheath heater.

3. Check the parts which have faults

described in 1, 2 (mechanical

model: disconnect thermostat

from the assembly).

Advertising
This manual is related to the following products: