Operation, Restrictor adjustment, Adjusting the fan speed – Lopi Yankee PS User Manual

Page 24: Travis industries, Not enough air, Too much air

Advertising
background image

2 4

Operation

© Travis Industries

4080728

1 0 0 - 0 1 1 5 6

Restrictor Adjustment

The restrictor is used to adjust airflow to the firepot. It should be adjusted to match the heat output setting
and burn the pellets at the appropriate rate. This keeps the firepot as clean as possible.

For low heat output settings the restrictor will need to be closed or near closed to limit the amount of air.
This prevents the stove from burning the pellet fuel faster than it is fed.

For medium heat output settings the restrictor will need to be opened to a medium position.

For high heat output settings the restrictor will need to be opened to a high position. This prevents the
firepot from over-filling with pellets and becoming clogged with ash clumps.

Keeping your firepot clean is the most important step to maintaining a safe and efficient stove. Check and
clean your firepot daily until you find the correct restrictor settings and appropriate firepot cleaning interval.

Not Enough Air

If clinkers (ashes that solidify into a clump)
develop or the flame appears lazy and slow to
blow the ash out of the firepot, pull the
restrictor outward until the flame becomes
active and the firepot holes remain clean.
NOTE: If the restrictor is fully out, yet the firepot
does not remain clean, the stove needs to be
cleaned and checked for air leaks (see
“Maintenance” section of this manual).

Too Much Air

If the flames are too active (small, flickering
flames) or if burning pellets are expelled from
the firepot, move the restrictor rod inwards until
the flame slows down and no burning pellets
are expelled (note: it is okay to have “glowing
embers” jump out of the firepot). Another
symptom of too much air is the heater “blowing
the fire out” – a condition in which the pellets
burn faster than they are fed (this is most
common on low).

Adjusting the Fan Speed

AUTO

OFF

MANUAL

H
E
A
T

F
A
N

UP

DOWN

UP

DOWN

MANUAL

MANUAL

START

AUGER

TRAVIS INDUSTRIES

HOUSE OF FIRE

TM

Press the “up” or “down”

button to adjust the fan

speed.

NOTE: When adjusting

the fan speed the HEAT

OUTPUT lights will flash

the fan speed setting for

one second.

Advertising