Maintenance, Travis industries, Door opening – Lopi Yankee PS User Manual

Page 29: Clearing the auger drop tube, Ab c d

Advertising
background image

Maintenance

2 9

© Travis Industries

4080728

1 0 0 - 0 1 1 5 6

Daily Maintenance (whenever using the stove) - Continued

Door Opening

WARNING

:

Make sure the
heater has fully
cooled
(approximately 25
minutes) before
opening the door
and conducting
service.

Phillips
Screwdriver

With the pawl free of the bracket,

the door may be swung open.

When securing

the door, make

sure the pawl fits

over the bracket

before tightening.

NOTE: Do not overtighten the pawl. This can

permanently damage the latch and

prematurely wear out the door gasket.

Door

Frame

Bracket (attached to side of

heater)

Pawl

Lock Nut

Clearing the Auger Drop Tube

In rare cases the auger drop tube will become plugged with pellets. If your heater fails to feed pellets (make sure
the hopper has pellets and the auger has been turning for 10 minutes after refueling), this is an indication of a
plugged drop tube. Follow these steps to clear the drop tube: a) Remove the screw on the drop tube; b) Slide
the fuel gate from the drop tube; c) Use a screwdriver to dislodge pellets from the top of the drop tube (make
sure to get both sides of the auger – you will get approximately 1/4 cup); and, d) Replace the fuel gate and
secure with the screw.

N O T E :

Earlier models do not have the fuel gate – proceed to step c to clear the drop tube.

WARNING

: Whenever the auger becomes jammed, it is an indication that the firepot has become plugged.

After clearing the pellets,

clean the firepot (see page

2 8

) and review the operating

instructions to verify the heater is working correctly and pellets are not piling up.

NOTE: Make sure this gate can

swing when in place. If it is

installed incorrectly, it will prevent

pellets from feeding correctly.

a

b

c

d

Advertising