Installation, For qualified installers only), Venting the pellet stove – Lopi Yankee PS User Manual

Page 9

Advertising
background image

Installation

(For Qualified Installers Only)

9

© Travis Industries

4080728

1 0 0 - 0 1 1 5 6

Venting the Pellet Stove

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
M A N U F A C T U R E R .

DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY
OTHER APPLIANCE OR STOVE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM
OF THIS UNIT.

USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT
THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER
WHEN PASSING THE VENT THROUGH CEILINGS (MAKE SURE TO
MAINTAIN CLEARANCE TO ANY COMBUSTIBLES).

No more than one tee and 180

°

of elbows (one tee with two 90

°

elbows, one tee with one

90

°

and two 45

°

elbows, etc.).

Maximum Venting
Distance

Vent must have a support
bracket every 5' of pellet vent
when exterior of structure

0 Feet

5 Feet

10 Feet (max.)

0 Feet

5 Feet

10 Feet

15 Feet

20 Feet

25 Feet

30 Feet

33 Feet

(max.)

The vent height and run

must not exceed the

distance shown in the
shaded region shown to the

right.

NOTE: To achieve optimum

performance, we

recommend keeping the
vent as short as possible

(horizontal run especially).

Venting into this shaded

area may require restrictor

adjustments. See the
section “Restrictor

Adjustment” for details.