Maintenance – Lopi Yankee PS User Manual

Page 28

Advertising
background image

2 8

Maintenance

© Travis Industries

4080728

1 0 0 - 0 1 1 5 6

Daily Maintenance (whenever using the stove) - Continued

Check Firepot for
Clinkers

If the flames seem to be
coming only from the sides,
or are orange/black, turn
the heater off and check for
clinkers (ashes that solidify
into a clump).

The most likely causes are:

Restrictor needs
adjustment (see
“Restrictor
Adjustment” in the
installation section of
this manual)

Poor pellet quality

The door or glass has
an air leak

The exhaust system
requires cleaning

Cleaning the Firepot

WARNING:

Make sure the heater
has fully cooled
(approximately 25
minutes) before
opening the door and
conducting service.

To clean the firepot, open
the door (see page 27) and
knock away any debris on
the firepot with a
screwdriver. If severely
clogged, remove the
firepot to gain better
access.

Advertising