Specifications

© Travis Industries

4080728

1 0 0 - 0 1 1 5 6

Heating Specifications

Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250 Sq. Feet

Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5

Maximum Burn Time on Low Burn** ......................................................................47 Hours

Hopper Capacity ..............................................................................................80 Pounds

*

Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected
by the fuel size, quality, and moisture level.

**

Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on fuel
quality may occur.

Dimensions

Air Inlet

(1-3/4"

Outside
Diameter)

Weight: 225 Lbs.

4"

Diameter
Exhaust

9-1/4"

16-1/2"

13"

5-1/4"

32"

23"

25"

This tab can be bent

out and used to hang

the scraper rod tool.

Electrical Specifications

Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz

Watts During Start-Up Sequence ...................................................................400 (approximately)

Watts During Operation ...............................................................................180 (approximately)

Fuel

• This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets.

See page 25 for details on using a corn pellet mix.

EPA Compliance

This heater has been tested exempt from EPA Phase II Requirements by OMNI-Test Laboratories, Inc.