Installation, For qualified installers only), Clearances - straight installation – Lopi Yankee PS User Manual

Page 8: Clearances - corner installation

Advertising
background image

8

Installation

(For Qualified Installers Only)

© Travis Industries

4080728

1 0 0 - 0 1 1 5 6

Clearances - Straight Installation

2”

Minimum**

6” Minimum

3” Minimum

9” Minimum

Through the Wall Installations

Interior Vertical Vents

Floor Protection

6” Minimum

9” Minimum

“Tee”

Vent

Clearance*

Clearances - Corner Installation

6” Minimum

Through the Wall Vents

3” Minimum

3” Minimum

45° Elbow

45°

Interior Vertical Vents

3”

Minimum

6” Minimum

3”

Minimum

Floor Protection

“Tee”

Vent Clearance*

2”

Minimum**

*

Install vent at clearance specified by the vent manufacturer.
NOTE: If interior vertical vent is used, the stove to backwall dimension is determined by the vent
being used. This dimension will vary depending on the brand of pellet vent used. To determine the
distance from the backwall to the stove, connect the "Tee" and add the vent clearance .

**

The floor protection must extend 2” or to the wall (whichever is less) – all vent clearances must be met.