background image

B-10

OPERATION

B-10

Parameter

Definition

Exit Setup Menu

P.0

This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit

the setup menu

P.1

Wire Feed Speed Units

This option selects which units to use for displaying wire feed speed. English = inches/minute

wire feed speed units (default). Metric = meters/minute wire feed speed units.

P.2

Arc Display Mode

This option selects what value will be shown on the upper left display while welding. Amps =

The left display shows Amperage while welding (default). WFS = The left display shows Wire

Feed Speed while welding.

P.3

Display Energy

This option selects whether or not energy is shown on the lower display while welding. The total

energy from the previous weld will persist on the lower display until another weld is started, or a

user interface control is changed. This option will only show up in the list if the power source is

capable of calculating energy (a power source firmware update may be necessary).

No = Energy will not be displayed (default). Yes = Energy is displayed.

P.12

Travel Carriage Start/Stop - Travel Starts

This option allows the adjustment of the start and end travel options for a travel carriage. Press

the Right Button to enter the option and rotate the Control Knob to select either starting or end-

ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to

select the desired function. After selecting the function, press the Left Button to save the func-

tion and back out to select another option. Rotate the Control Knob to make another selection,

or press the Left Button to exit this option.

P.12

Travel Carriage Start/Stop - Travel Ends

This option allows the adjustment of the start and end travel options for a travel carriage. Press

the Right Button to enter the option and rotate the Control Knob to select either starting or end-

ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to

select the desired function. After selecting the function, press the Left Button to save the func-

tion and back out to select another option. Rotate the Control Knob to make another selection,

or press the Left Button to exit this option.

P.13

Arc Force Adjustment Options

This option allows the adjustment of Arc Force values for Start, Weld and Crater. Press the

right Mode Select Button to enter the option and rotate the Set knob to select the desired weld

state to adjust. Press the right button again to adjust the value on the upper left knob. Press

the left button to save the value and back out to select another weld state. Rotate the Set knob

to make another selection, or press the left button to exit this option. P.13 will not appear if the

presently selected weld mode does not support Arc Force.

P.14

Reset Consumable Weight

Use this option to reset the initial weight of the consumable package. Press the Right Button to

reset the consumable weight. This option will only appear with systems using Production

Monitoring.