E-6

TROUBLESHOOTING

E-6

MAXsa™ 10 CONTROLLER

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Err 263 No usable weld modes.

1. The power source does not have

any welding programs loaded.

2. See the power source Instruction

M a n u a l f o r l o a d w e l d i n g p r o -

grams.

If all recommended possible areas of

misadjustment have been checked

and the problem persists, Contact

your local Lincoln Authorized Field

Service Facility.

ARCLINK SYSTEM ERROR CODES

Below are errors implemented for the MAXsa™ 10.

Typical User Interface 3 digit error codes (not blinked on the status LED).

Error

Code

N/A

28

83

84

Source

User Interface

Feeder

Feeder

Feeder

UI Text

" Limits Exceed "

"Gear Box Type"

“OUTPUT DISABLED”

" UI Shutdown 1 "

" UI Shutdown 2 "

Reason

When a mode is selected with a work point low limit

greater than the high WFS limit. (no event is logged)

The shutdown 2 input on the Feeder Board is open and

P.21 is selected for “Output Disable”

The shutdown 1 input on the Feeder Board is open.

The shutdown 2 input on the Feeder Board is open.

Error

Code

213

215

247

274

275

276

277

278

281

282

Source

User Interface

UI Text

Power Source

is Off-Line

Feeder Board is Off-Line

N/A

N/A

N/A

N/A

N/A

N/A

(Varies based on the

error type and who

caused the error)

(Varies based on the

error type and who

caused the error)

Reason

User Interface could not communicate with control board

in power source.

Either no feed head board is connected, being repro-

grammed or experiencing a fatal event.

Arc control has a latched fault. The UI will indicate a

Reset button needs to be pressed to clear the fault.

Weld set change required clearing of user memory.

UI memory could not be saved. Contact Lincoln Electric

Service Department for further support.

UI memory could not be restored. Contact Lincoln

Electric Service Department for further support.

UI memories were converted due to change in number of

UI parameters. Info only.

UI limits were converted due to change in number of UI

parameters with limits. Info only.

Internal Error. Collect all displayed values and contact

Lincoln Electric Service Department.

Internal Error. Collect all displayed values and contact

Lincoln Electric Service Department.