Operation, Warning – Lincoln Electric IM10023 User Manual

Page 29

Advertising
background image

TOUCH SENSE

The Touch Sense option, when enabled, allows the

operator to feed the wire forward until it touches the

workpiece. When contact to the work is made, the

wire will stop and the flux hopper (if used) will activate

to put flux around the wire and fill the flux feed sys-

tem. The flux hopper will stay active until the Feed

Forward button is released.

If the Touch Sense is enabled the Power Source

output is ON as long as the Feed Forward button

is held. Avoid touching any portion of the weld cir-

cuit while feeding down.

If the Touch Sense option is disabled, the wire is

“cold” during the Feed Forward time. It will not stop

when it touches the work and the flux hopper will not

activate.

LOCKOUT / SECURITY

The MAXsa™ 10 can be configured to prevent the

operator from changing selected User Interface panel

controls. By default, the welder will be able to change

the weld mode, all relevant wave controls and all rele-

vant start and end options.

Note that when an option is locked, its value can still

be monitored. For example, if start and end options

are locked, the welder can still press the right Mode

Select Panel Pushbutton and see the value set for

Start Time. If the welder attempts to change its value,

a message will briefly appear on the Mode Select

Panel indicating "MSP Option is LOCKED

The lockout features are only available through

the use of Power Wave Manager.

WARNING

B-14

OPERATION

B-14

MAXsa™ 10 CONTROLLER

Parameter

Definition

P.506

Set User Interface Passcode

Prevents unauthorized changes to the equipment. The default passcode is zero which allows

full access. A nonzero passcode will prevent unauthorized: changes to memory limits, saving to

memory (if P.502 = Yes), changes to setup parameters (if P.505 = Yes).

This parameter can only be accessed using Power Wave Manager software.

P.509

UI Master Lockout

Locks all user interface controls, preventing the operator from making any changes. This para-

meter can only be accessed using Power Wave Manager software.