Setting data rates – Paradyne 6800 User Manual

Page 261

Advertising
background image

COMSPHERE 6800 Series Network Management System

5-100

January 1997

6800-A2-GN22-30

4. The following counter appears:

Elapsed Time 00:00:00

The counter increments every five seconds. During this procedure, the keyboard is locked
and you cannot stop the removal. For large ANALYSIS network configurations, the
removal may take longer than one hour. When the process is completed, the following
message appears:

“System name” removed from the system

5. The ANALYSIS Selection menu appears again (see Step 1 for menu). To remove

additional 6510’s, return to Step 1. To exit the procedure,

TYPE: 4

PRESS: Enter

6. When asked to display the system summary,

TYPE: 4

PRESS: Enter

7. Reset the host computer. For additional information, refer to Chapter 6, System Start-up

and Shutdown.

Setting Data Rates

The default data rate for the physical link between the 6800 Series NMS and the ANALYSIS NMS
is 9600 bps. This rate may be changed as follows.

For the ANALYSIS controller, run syssetup following the procedures in the ANALYSIS 6510
Automated Network Management System Reference Manual
.

For the 6800 Series NMS, edit the port configuration for the port connecting the ANALYSIS
controller using the Edit Port Configuration (edpc) command. In the input form for the edpc
command change the number in the speed field. Changing the number in this field changes the data
rate.

The initial data rate is 9600. Valid data rates are 1200, 2400, 4800, and 9600. The recommended
data rate for local connections is 9600 bps. For remote connections, the recommended data rate is
the highest rate of your data communications equipment. If an invalid rate is entered, the system
uses the initial rate set. CHANGES IN RATES DO NOT TAKE EFFECT UNTIL THE SYSTEM
STOPS AND NMS IS RESTARTED. YOU MUST RESET THE ANALYSIS NMS FOR THE
CHANGES TO TAKE EFFECT.