Signal parameters on ils display – Procom VOR/ILS Analyzer EVS200 User Manual

Page 29

Advertising
background image

VOR/ILS Analyzer EVS200

0796.1800.02

E-8

20

Chapter 3: Operation

Signal parameters on ILS display

Following signal parameters are indicated on the display:

display indication

description

measuring value

FREQ. (MHZ)

receiver frequency in MHz (numerical) and
bargraph center frequency indication in kHz

MHz

LEVEL (dBm)

receiver signal in dBm (numerical) and
bargraph indication (the lower bargraph
shows the set squelch threshold)

dBm

DISPL 1/2

AM-MOD.(90HZ)

AM modulation depth (90 Hz)

%

AM-MOD.(150HZ)

AM modulation depth (150 Hz)

%

DDM

differences in depth of modulation

DDM-value

(non-dimension value)

µ

A

%

SDM

total modulation factor

SDM-value

(non-dimension value)

µ

A

%

PHI (90/150)

phase shift (90 Hz/150 Hz)

degree

DISPL 2/2

ID AF-FREQ.

AF frequency (1020 Hz)

Hz

ID AM-MOD.

AM modulation depth of AF frequency

%

VOICE AM-MOD.

AM modulation depth in the range of
300 to 3000 Hz

%

Y / t Setup

Range 1 to 4

XY value scaling in localizer /
glideslope
mode at DSP-Out.

%

STORE
DDM menu

Locations 1 to 120

DDM/SDM results