Procom VOR/ILS Analyzer EVS200 User Manual

Page 47

Advertising
background image

VOR/ILS Analyzer EVS200

0796.1800.02

E-8

38

Chapter 3: Operation

Command BW0

command

function

BW0

<bandwidth information >

8-kHz bandwidth setting

The command BW0 enables the switching over to the 8-kHz bandwidth in the ILS mode and in the
"

∆∆∆∆

level" mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

input:

BW0 <CR>
bw0 <CR>

READY <CR/LF>
READY <CR/LF>

Command BW1

command

function

BW1

<bandwidth information>

30-kHz bandwidth setting

The command BW1 enables the switching over to the 30-kHz-IF bandwidth in the ILS mode and in
the "

∆∆∆∆

level" mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

input:

BW1 <CR>
bw1 <CR>

READY <CR/LF>
READY <CR/LF>