Level-mode – Procom VOR/ILS Analyzer EVS200 User Manual

Page 58

Advertising
background image

VOR/ILS Analyzer EVS200

0796.1800.02

E-8

49

Chapter 3: Operation

∆∆∆∆

Level-Mode

Command SR

command

function

SR

<Set REF>

reference level setting

The command SR is for setting the actual receiver level as a reference level in the reference level
window "

∆∆∆∆

level"-mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

input:

SR <CR>
sr <CR>

READY <CR/LF>
READY <CR/LF>

Command LR

command

function

LR

<level reference>

reference level query

The command LR reads the actual set reference level in the "

∆∆∆∆

Level" mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

LR <CR>
lr <CR>

e.g.

-48.1dBm <CR/LF>

e.g.

-48.1dBm <CR/LF>

Command LD

command

function

LR

<level delta>

∆∆∆∆

-Level query

The command LD reads the actual

∆∆∆∆

-Level in the "

∆∆∆∆

Level" mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

LD <CR>
ld <CR>

e.g.

-000.0dBm <CR/LF>

e.g.

-000.0dBm <CR/LF>