DSL Ports (DSL Parameters) 8312/8314 ReachDSL/MVL Cards

(continued)

A-B-A

CO On-hook Voltage Drop Threshold – 0V, 6V (Default = 6V). Used in combination with
the SN On-hook Voltage Drop Threshold. See

CO and SN On-hook Voltage Drop

Threshold Settings

below.

SN On-hook Voltage Drop Threshold – 34V, MaxV (Default = 34V). Used in
combination with the CO On-hook Voltage Drop Threshold.

Thresholds for Trap Messages:

Margin Threshold – Sends a trap message if the margin on either end falls below the
selected value. Enter a value for the margin threshold trap (–7 dB to +14 dB)
(Default = 0). Enter D to disable trap.

Link Down Ct – Sends a trap message if the number of MVL link down events in
15 minutes exceeds the selected value. Enter a value for the Link Down Count Trap
(0–1000) (Default = 0). Enter D to disable trap.

Table 3-2.

Ports Options (6 of 9)

CO and SN On-hook Voltage Drop Threshold Settings

When . . .

Set the CO On-hook
Voltage Drop Threshold
to . . .

Set the SN On-hook
Voltage Drop Threshold
to . . .

The CO does NOT have a DC
blocking CAP CO filter

6V

34V

The CO does have a DC
blocking CAP CO filter

0V

34V

Both the CO and the SN have
DC blocking CAP filters
(This creates an always
off-hook condition.)

0V

MaxV