PSC FALCON 315 User Manual

Page 25

Advertising
background image

Standard

Setup

Quadrant Mode

The scrolling list option defines the rules by which the terminal display is positioned in
the larger host display. As defined by Twin Client, quadrants are fixed position
“windows” in the host display, and the terminal display is located on whatever quadrant
contains the current cursor position.

Off

disables quadrant processing and Twin Client simply centers the current host

input field in the terminal display.

On

enables quadrant processing. However, input fields that cross quadrant

boundaries result in a shift to the left in order to locate as much of the current input
field on the terminal display.

Soft

always positions on a quadrant boundary regardless of input field boundaries.

Viewing keys are enabled.

Hard

is the same as

Soft

except the viewing keys are disabled.

Lock

locks the terminal display origin (upper left corner) to fixed row and column

(x,y) coordinates in the host display. The coordinates are zero-based.

Font

These check boxes enable (checked) or disable (unchecked) the display of characters in
double high and double wide font.

Supported Equipment Manual

May, 2006

2-17

Advertising