44

In the unit, there is a video signal delay in the camera, which
is required or the process of converting video images taken
with the image-shooting element from the progressive
signals to the interlace signals. Since time is required for
making the 2:3 pull-down from the 24P frame, there is a
video signal delay in the camera. When recording from a
device that can record images without a delay and the unit is
connected in parallel, it is necessary to synchronize the time
code. To set this timing, open the <TC UB> screen from the
VTR MENU page and set it in the TC VIDEO SYNCRO item.
Set by referring to the connection example.

Setting of the TC VIDEO SYNCRO item

Example 3:
When the unit and an external device are locked to the
external time code generator, which is connected externally,
and when simultaneous recording is made by using the TC
OUT output signals.

Item

Variable

range

Remarks

TC VIDEO
SYNCRO

0
1
2
3

For setting to correct the time code
according to the delay of video signals.
0: Do not correct.
1: To delay the time code to be input

according to the timing of the video
images.

2: To forward the time code to be output

according to the timing of the video
images.

3: To delay the time code to be input and

forward the time code to be output,
respectively, according to the timing of
the video images.

Chapter 4 Adjustments and settings for recording

(continued)

Example 2: When connecting a multiple number of units and

using one of them as the reference unit

GENLOCK IN

TC IN

TC OUT

GENLOCK IN

TC IN

TC OUT

TC OUT

Reference unit

To the next camera

<Note>
The system can be configured with multiple units by opening
the <GENLOCK> screen from the SYSTEM SETTING page
and setting the GL PHASE item to the connector using menu
operations.
The phase of the time code can correspond to either the HD-
Y output signals of the MON OUT connector or VBS output
signals of the VIDEO OUT connector. However, the same
value should commonly be set to the GL PHASE for all
cameras. If different values coexist in the system, the
shooting timing may not correspond to each other.

Reference video signal

Setting of GL PHASE

MON OUT (HD-Y)

HD SDI

VIDEO OUT (VBS)

COMPOSIT

Setting of GL PHASE

MON OUT (HD-Y)

or

VIDEO OUT (VBS)

MON OUT (HD-Y)

or

VIDEO OUT (VBS)

MON OUT (HD-Y)

or

VIDEO OUT (VBS)

Item

Variable

range

Remarks

GL PHASE

HD SDI
COMPOSIT

For selecting the output signals that lock
phases to the signals that are input in the
GENLOCK IN connector.
HD SDI:

For locking the HD SDI signals to the
GENLOCK input.
For the down converter output signals,
the start position of the video delays by
about 90 lines.

COMPOSIT:

For locking the down converter output
signals to the GENLOCK input.
For the HD SDI output signals, the start
position of the video gains by about 90
lines.

TCG

TC OUT

TC OUT

TC IN

REF IN

TC IN

TC IN

GENLOCK IN

VIDEO IN

SDI IN

HD SDI IN

AJ-HDX900

DAT

External time code generator

Device that records images without a delay

VTR etc.

Settings of the TC
VIDEO SYNCRO item: 1

Reference video signal

MON OUT

or

VIDEO OUT

Advertising