Matsushita part number K1AB120H0001

Maker part number

HR12-14RA-20SC

(Hirose Denki)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Maker part number

HR10A-10R-10SC (71)

(Hirose Denki)

Connector at the cable side

Maker part number

HR10A-10P-10P(73)

(Hirose Denki)

1

2

4

5

6

7

8

9

10

3

REMOTE

1

CAM DATA (H)

Data from the camera to the remote control (H)

2

CAM DATA (C)

Data from the camera to the remote control (C)

4

CAM CONT (C)

Control signals from the remote control to the camera (C)

5

RC-ON

Identification signals of the remote control
Low: ON

6

RC VIDEO OUT

Video signals output to the remote control

7

RC VIDEO GND

GND of the video signals to the remote control

8

NC

Not used

9

UNREG 12V

DC +12 V power supply (AJ-RC10G: Max. 0.75 A)

10

GND

GND

3

CAM CONT (H)

Control signals from the remote control to the camera (H)

VF

1

UNREG-12V

DC +12 V power supply (AJ-HVF21G: About 0.35 A)

2

UNREG-12V

DC +12 V power supply

4

VF-PB-GND

GND for the viewfinder P

B

signals

5

VF-PR-GND

GND for the viewfinder P

R

signals

6

VF-Y

Viewfinder Y signals output

7

VF-Y-GND

GND for the viewfinder Y signals

8

VF-CLK

Serial data clock pulse signals

9

VF-WR

Pulse signals for reading serial-parallel conversion
data

10

VF-DATA

Serial data signals for serial-parallel conversion

11

UNREG-GND

GND

12

ZEBRA-SW

ON/OFF of the zebra signals

13

PEAKING

Control of the peaking (not used)

14

SPARE

Standby (not used)

15

VF-PR

Viewfinder P

R

signal output

16

VF-PB

Viewfinder P

B

signal output

17

MARKER-SW

ON/OFF of the marker (not used)

18

FRONT-VR

FRONT AUDIO LEVEL adjustment (not used)

19

VR-GND

GND for the FRONT AUDIO LEVEL (not used)

20

UNREG-GND

GND

3

A9.0V

DC +9 V power supply (not used)

Caution:
Total amount of current from the respective connectors for DC OUT, REMOTE, VF,
and LENS should not exceed 2.5 A.