16 discrete 2 of 5, 17 rss code, 16 discrete 2 of 5 5.27.1.17 rss code – Psion Teklogix ISO 9001 User Manual

Page 163: Reduced space symbology), Field size/char, Enabled, Set length l1 and set length l2, Enable, Enable rss-14, Enable rss limited

Advertising
background image

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 145

Chapter 5: Settings

Decoded (Internal) Scanners

Field Size/Char

Refer to page 136 for details.

5.27.1.16 Discrete 2 of 5

Enabled

Set this parameter to on to enable “Discrete 2 of 5”.

Set Length L1 And Set Length L2

Lengths for “Discrete 2 of 5” can be set for Any length, Length within a range, One
discrete length
or Two discrete lengths. The length of a code refers to the number of
characters (i.e., human readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths
where you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a
selected length. Choosing Two discrete lengths allows you to decode only those
codes containing two selected lengths. Length within a range allows you to decode
a code type within a specified range from 1 to 12.

Field Size/Char

Refer to page 136 for details.

5.27.1.17 RSS Code

Enable

Setting this parameter to on enables “2D RSS Code” scanning capability.

Enable RSS-14

(Reduced Space Symbology)

RSS-14 code can be either purely linear or split in half with one half stacked on top
of the other half. Stacking the code reduces the bar code length, and providing the
nominal height of the code is maintained, it can be omni-directionally scanned.

Enable RSS Limited

“RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade
item number) that begin with either a 0 or a 1. It is not stackable and is not designed
to be read omni-directionally.

Advertising